Specimen collection guidelines
v
Specimen Collection and Labeling
Requirements
v
General
Microbiology Specimen Collection and Storage
v
Collection
Guidelines for Sexually Transmitted Diseases
|
Tube |
Tube name |
Anticoagulant |
Mix by inverting |
Applications |
|
|
Green Microtainer® With Gel Seperator |
Lithium Heparin by capillary collection |
10 times |
For plasma determinations in chemistry |
|
|
Light Green-Top |
Lithium Heparin |
8 times |
For plasma determinations in chemistry |
|
|
Green-Top |
Lithium Heparin Sodium Heparin |
8 times |
For plasma determinations in chemistry |
|
|
Green/Grey Top |
Lithium Heparin |
8 times |
For plasma determinations in chemistry |
|
|
Grey-Top |
Sodium Fluoride and Potassium Oxalate |
8 times |
For glucose determinations |
|
|
Lavender Microtainer®
tube |
EDTA for capillary collection |
10 times |
For whole blood hematology determinations |
|
|
Lavender-Top |
EDTA |
8 times |
For whole blood hematology determinations |
|
|
Light Blue |
Sodium Citrate |
3-4 times |
For coagulation determinations |
|
|
Red Top |
No anticoagulant or gel barrier |
0 times |
For serum determinations in chemistry |
|
|
Red/Grey Top |
No anticoagulant With gel barrier |
5 times |
For serum determinations in chemistry |
|
|
Royal Blue |
EDTA or plain |
5-8 times |
For trace element analysis, toxicology, and
nutritional chemistry |
|
|
Yellow Top |
ACD |
8 times |
For Blood Bank studies, and HLA phenotyping |
|
|
Yellow Top (Isolator) |
SPS |
8 times |
For blood culture collection in Microbiology |
|
|
Gold Top, Serum Seperator
Tube (SST) |
Clot activator and gel For serum seperations |
5 times |
For serum determinations in chemistry. DO NOT use for
Cold Agglutinins, Cryoglobulin, or Viscosity tests |